1. Home
  2. /
  3. Analysers
  4. /
  5. Testo 340 flue gas analyser for use in industry

Testo 340 flue gas analyser for use in industry

Testo 340 Flue gas analyser is an easy-to-use measuring instrument. Testo 340 analyzer has an O2 sensor, but can connect three more. The device can also be used outdoors.

Testo 340 Flue gas analyser for use in industry:

  • Can measure CO, Low CO, NO, Low NO, NO2 and SO2
  • Can be used in environments with high gas concentration
  • Includes pre-calibrated gas sensors for quick and easy replacement

TECHNICAL SPECIFICATION:

Differential Pressure – Piezoresistive

Measuring range: -200 hPa to 200 hPa

Accuracy: ±0.5 hPa (-49.9 to 49.9 hPa); ±1.5 % of mv (Remaining Range)

Resolution: 0.1 hPa

Absolute Pressure

Measuring range: +600 hPa to +1150 hPa

Accuracy: ±10 hPa

Resolution: 1 hPa

Flue gas O₂

Measuring range: 0 Vol.% to 25 Vol.%

Accuracy: ±0.2 Vol.%

Resolution: 0.01 Vol.%

Reaction time: < 20 s

Flue gas CO (with H₂-compensation)

Measuring range: 0 ppm to 10000 ppm

Accuracy: ±10 ppm or ±10 % of mv (0 to 200 ppm); ±20 ppm or ±5 % of mv (201 to 2000 ppm); ±10 % of mv (2001 to 10000 ppm)

Resolution: 1 ppm

Response time: < 40 s

COlow (with H₂ compensation)

Measuring range: 0 ppm to 500 ppm

Accuracy: ±2 ppm (0 to 39.9 ppm) ±5 % of mv (Remaining Range) data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K.

Resolution: 0.1 ppm

Response time: < 40 s

Dūmų dujos NO

Measuring range: 0 ppm to 4000 ppm

Accuracy: ±5 ppm (0 to 99 ppm); ±5 % of mv (100 to 1999 ppm); ±10 % of mv (2000 to 4000 ppm)

Resolution: 1 ppm

Reaction time:< 30 s

Flue gas Nolow

Measuring range: 0 ppm to 300 ppm

Accuracy: ±2 ppm (0 to 39.9 ppm); ±5 % of mv (Remaining Range)

Resolution: 0.1 ppm

Reaction time:< 30 s

Flue gas NO₂

Measuring range: 0 ppm to 500 ppm

Accuracy: ±10 ppm (0 to 199 ppm); ±5 % of mv (Remaining Range)

Resolution: 0.1 ppm

Response time: < 40 s

Flue gas SO₂

Measuring range: 0 to 5000 ppm

Accuracy: ±10 ppm (0 to 99 ppm); ±10 % of mv (Remaining Range)

Resolution: 1 ppm

Response time: < 40 s

Differential Pressure flue gas Draught – Piezoresistive

Measuring range: -40 hPa to +40 hPa

Accuracy: ±0.03 hPa (-2.99 to +2.99 hPa); ±1.5 % of mv (Remaining Range)

Resolution: 0.01 hPa

Temperature

Measuring range: -40 °C to +1200 °C

Accuracy: ±0.03 hPa (-2.99 to +2.99 hPa); ±1.5 % of mv (Remaining Range)

Resolution: 0.1 °C

Flue gas degree of effectivity, Eta (calculated)

Measuring range: 0 % to 120 %

Resolution: 0.1 %

Flue gas loss (calculated)

Measuring range: 0 % to 99.9 %

Resolution: 0.1 %

Flue gas dewpoint (calculated)

Measuring range: 0 °Ctd to 99.9 °Ctd

Resolution: 0.1 °Ctd

Flue gas CO₂ calculation (calculated from O₂)

Measuring range: 0 to CO₂ max

Accuracy: ±0.2 Vol.%

Resolution: 0.1 Vol.%

Response time: < 40 s

General technical information

Weight: 960 g

Dimensions: 283 x 103 x 65 mm

Operating temperature: -5 °C to +50 °C

Protection class: IP40

Connectable probes: 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure

Battery life: > 6h

Display size: 160 x 240 px

Power supply: Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A

User defined fuels: 10 user-defined fuels incl. test gas as fuel

Maximum memory: 100 folders

Storage per folder: 10 sites

Storage per site: Max. 200 logs

Storage temperature: -20 °C to +50 °C

DELIVERY SCOPE: Testo 340 flue gas analyzer, calibration protocol, shoulder strap, O2 sensor and integrated flow and pressure difference measurements.

PRODUCT CODE: 0632 3340

Want to know more?

Fill in the inquiry form and we will get back to you!





    Similar products