{"id":3593,"date":"2023-06-12T13:22:46","date_gmt":"2023-06-12T10:22:46","guid":{"rendered":"https:\/\/axs.eu\/produktai\/sensors-for-ph-measurement"},"modified":"2025-09-02T10:50:29","modified_gmt":"2025-09-02T07:50:29","slug":"sensors-for-ph-measurement","status":"publish","type":"produktai","link":"https:\/\/axs.eu\/en\/products\/sensors-for-ph-measurement","title":{"rendered":"Sensors for pH measurement"},"content":{"rendered":"<p id=\"tw-target-text\" class=\"tw-data-text tw-text-large tw-ta\" dir=\"ltr\" data-placeholder=\"Vertimas\"><strong><span class=\"Y2IQFc\" lang=\"lt\">We supply glass and shatterproof sensors for measuring acidity (pH).<\/span><span class=\"Y2IQFc\" lang=\"lt\"><a href=\"https:\/\/www.knick-international.com\/en\/products\/process-analytics\/industrial-sensors\/oxygen-sensors\/\" target=\"_blank\" rel=\"noopener\">Knick<\/a>&#8216;s pH sensors can be used in a wide range of industries, from water management to pharmaceuticals, which have extremely high demands.<\/span><span class=\"Y2IQFc\" lang=\"lt\">Digital pH <\/span><span class=\"Y2IQFc\" lang=\"lt\">sensors are used with a variety of <\/span> <span class=\"Y2IQFc\" lang=\"lt\">Knick fittings such as. SensoGate and Ceramat, as well as submersible, built-in or high-pressure applications.<\/span><\/strong><\/p>\n<h4 dir=\"ltr\" data-placeholder=\"Vertimas\"><span class=\"Y2IQFc\" lang=\"lt\">Knick offers the following pH sensors:<\/span><\/h4>\n<ul>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-pH-jutiklis-SE-503.pdf\" target=\"_blank\" rel=\"noopener\"><strong>SE 503<\/strong><\/a> &#8211; standard water\/wastewater pH sensor. It is a robust and low-maintenance instrument for the analysis of drinking, process or industrial water.<\/li>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-pH-jutiklis-SE-515-Memosens.pdf\" target=\"_blank\" rel=\"noopener\"><strong>SE 515 Memosens<\/strong><\/a> &#8211; sensor for water and wastewater analysis. Wit<span class=\"Y2IQFc\" lang=\"lt\">h<\/span> <span class=\"Y2IQFc\" lang=\"lt\">Memosens technology.<\/span><\/li>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-ph-jutiklis-SE-547-Memosens.pdf\" target=\"_blank\" rel=\"noopener\"><strong>SE 547 Memosens<\/strong><\/a> &#8211; unbreakable, ISFET, digital sensor. Wit<span class=\"Y2IQFc\" lang=\"lt\">h<\/span> <span class=\"Y2IQFc\" lang=\"lt\">Memosens technology.<\/span><\/li>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><strong><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-SE554-pH-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\">SE 554<\/a>, <a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-SE-554-Memosens-pH-ORP-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\">SE 554 pH\/ORP<\/a>, <a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-SE-554-Memosens-pH-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\">SE 554 Memosens<\/a><\/strong> is a low-maintenance sensor for precision pH and ORP measurement in the chemical industry. Wit<span class=\"Y2IQFc\" lang=\"lt\">h<\/span> <span class=\"Y2IQFc\" lang=\"lt\">Memosens technology.<\/span><\/li>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><strong><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-SE-555-Memosens-ph-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\">SE 555 Memosens<\/a>, <a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2025\/08\/SE555-pH-orp-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\">SE 555 pH\/ORP<\/a>, <a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-SE-555-ph-jutiklis-VP.pdf\" target=\"_blank\" rel=\"noopener\">SE 555 VP<\/a>, <a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-SE-555-ph-jutiklis-VP.pdf\" target=\"_blank\" rel=\"noopener\">SE 555 (Koax<\/a>) <\/strong>\u2013 sterile pH sensor used in the pharmaceutical and food industries. Can take measurements in aggressive media. Wit<span class=\"Y2IQFc\" lang=\"lt\">h<\/span> <span class=\"Y2IQFc\" lang=\"lt\">Memosens technology.<\/span><\/li>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><strong><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-SE-557-Memosens-ph-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\">SE 557 Memosens<\/a>, <a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-se-557-VP-pH-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\">SE 557 VP <\/a><\/strong>&#8211; sensor for use in high pressure media and specific pH measurements. Very precise, filled with electrolyte fluid. Wit<span class=\"Y2IQFc\" lang=\"lt\">h<\/span> <span class=\"Y2IQFc\" lang=\"lt\">Memosens technology.<\/span><\/li>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-ph-jutiklis-SE-558-Memosens.pdf\" target=\"_blank\" rel=\"noopener\"><strong>SE 558 Memosens<\/strong><\/a><strong>, <a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-ph-jutiklis-SE-558-VP.pdf\" target=\"_blank\" rel=\"noopener\">SE 558 VP <\/a><\/strong>&#8211; for simple pH measurement of ultrapure water. Wit<span class=\"Y2IQFc\" lang=\"lt\">h<\/span> <span class=\"Y2IQFc\" lang=\"lt\">Memosens technology.<\/span><\/li>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-se-559-Memosens-ph-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\"><strong>SE 559 Memosens<\/strong><\/a> &#8211; for simple pH measurements in the water and chemical industries. Digital, wit<span class=\"Y2IQFc\" lang=\"lt\">h<\/span><span class=\"Y2IQFc\" lang=\"lt\">Memosens technology.<\/span><\/li>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><strong><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-se-560-memosens-pH-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\">SE 560 Memosens<\/a>, <a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/knick-se-560-ph-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\">SE 560<\/a><\/strong> &#8211; for pH measurement in ultra-low temperature media. Digital, wit<span class=\"Y2IQFc\" lang=\"lt\">h<\/span><span class=\"Y2IQFc\" lang=\"lt\">Memosens technology.<\/span><\/li>\n<li dir=\"ltr\" data-placeholder=\"Vertimas\"><a href=\"https:\/\/axs.eu\/wp-content\/uploads\/2023\/06\/Knick-SE-571-Memosens-pH-jutiklis.pdf\" target=\"_blank\" rel=\"noopener\"><strong>SE 571 Memosens <\/strong><\/a>&#8211; for use in acidic, alkaline media and similar environments. Low maintenance. Digital, wit<span class=\"Y2IQFc\" lang=\"lt\">h<\/span><span class=\"Y2IQFc\" lang=\"lt\">Memosens technology.<\/span><\/li>\n<\/ul>\n","protected":false},"featured_media":3033,"parent":0,"menu_order":0,"template":"","produktu-kategorijos":[225],"class_list":["post-3593","produktai","type-produktai","status-publish","has-post-thumbnail","hentry","produktu-kategorijos-sensors"],"acf":[],"_links":{"self":[{"href":"https:\/\/axs.eu\/en\/wp-json\/wp\/v2\/produktai\/3593","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/axs.eu\/en\/wp-json\/wp\/v2\/produktai"}],"about":[{"href":"https:\/\/axs.eu\/en\/wp-json\/wp\/v2\/types\/produktai"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/axs.eu\/en\/wp-json\/wp\/v2\/media\/3033"}],"wp:attachment":[{"href":"https:\/\/axs.eu\/en\/wp-json\/wp\/v2\/media?parent=3593"}],"wp:term":[{"taxonomy":"produktu-kategorijos","embeddable":true,"href":"https:\/\/axs.eu\/en\/wp-json\/wp\/v2\/produktu-kategorijos?post=3593"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}